Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8811699
- Product Categories
- Friendly Links
Information Name: | Supply LF-VIS split dual power automatic transfer switch |
Published: | 2012-03-27 |
Validity: | 30 |
Specifications: | |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | LF-VIS split dual power automatic transfer switch ■ Product Overview □ ASQ1-1250LF series automatic transfer switch as the core of the latest computer control systems, design of electromagnetic compatibility, interference immunity and long-term stable and reliable, with split large screen backlit LCD display, operation, simple alert and highly intelligent is an ideal mechatronics new dual power automatic switching system, is a replacement product of similar domestic products; □ Dual Power Automatic Transfer Switch for AC 50/60Hz, rated voltage below 400V, rated current of 1250A the following dual power supply system, to achieve common power supply (N) and standby power (R) automatic switching (which can also set to manual switching), dual power supply achieve unattended substation. This product is suitable for the important place of the special class, the class I electric power system, high-rise buildings, residential quarters, military installations, hospitals, airports, terminals, shopping malls, communications, fire protection, metallurgy, chemicals, textiles, petroleum, coal, etc. do not allow the power outage; □ mechatronics design, high-current, simple structure, switching very rapidly; switching mode, the function can meet a variety of applications, the grid on the grid, the grid generator, since the automatic recovery, since a vote of no self-complex. ■ Dual power switch models ASQ1-225 LF / 160? 4 CB RX Enzo CB level dual power transfer switch Frame current: 63,100,225,400,630,800,1250 Design Category: LF-split VIS type Rated current: 63 shell frame -6,10,16,20,25,32,40,50,63 100 shell frame -16,20,25,32,40,50,63,80,100 225 shell frame -100,125,140,160,180,200,225 400 shell frame -225,250,315,350,400 630 shell frame -400,500,630 800 shell frame -630,700,800 1250 shell frame -800,1000,1250 Number of poles: 3P, 4P Electrical level: CB-with overload, short circuit protection; Ways of working: R-automatic recovery S-self-investment and self-re- F-grid power generation Optional features: X-fire linkage signal ■ technical conditions □ standard: GB14048.1 GB14048.2, GB14048.11 □ Pollution Level: III level □ electrical level: CB level □ Category: AC-33B of the □ Altitude: ≤ 2000m □ ambient temperature: -5 ℃ ~ +40 ℃, the need to consider more than the maximum temperature derating; when the maximum temperature of 40 ℃, humidity no more than 50%, and take measures to prevent condensation phenomenon of temperature changes that may arise. ■ structural features Double power automatic switch is composed of two parts of the device body and the intelligent automatic controller. □ device body by two with motor operating mechanism of circuit breaker (model specifications, see the terms of the technical parameters) and accessories (auxiliary alarm contacts, etc.), composed of the institution of mechanical interlock, electrical interlock, fuses, terminals, and all zero The components installed on a metal plate. □ automatic controller by the new microcontroller and output modules. Through a dedicated aviation plug interface and special length not exceeding 2 m shielded cable connection between the two, composed of intelligent control systems, intelligent system control power supply voltage is 220V, 50/60Hz. ■ PERFORMANCE □ controller at the same time the two voltage detection, power supply voltage higher than the rating of 110% (adjustable) ruled over-voltage, lower than the rating of 85% (adjustable) judgments owed to the voltage (or loss) The microcomputer control circuit logic to determine the above test results, the results of sub-gate delay (adjustable) circuit to drive the corresponding instruction issued to the motor operating mechanism or closing instructions, the above test results in the intelligent automatic control panel LCD display displayed can also connected through the serial port and the computer software control for the user to find out the reasons, in order to repair the fault line in the shortest possible time, dual power supply to restore the original state. □ intelligent automatic controller to control functions are divided into three △ automatic recovery (R) apply to the grid and the grid. Automatic controller to automatically switch the two power supply (ie, common power supply and standby power), the normal state by the common power supply. Common power failure or abnormal (any one phase voltage, overvoltage, undervoltage, loss of pressure or phase), automatic switch to standby power supply, when the commonly used power is restored, automatically returns to the common power supply. When the standby power failure or abnormal (any one phase voltage overvoltage, undervoltage, loss of pressure or phase), the controller issued a common or standby power alarm. △ a vote of no self-complex (S) on the grid with the grid. Since the vote not automatically switch to the automatic controller from complex two-way power (ie, common power supply and standby power). In either a power abnormal (either a phase voltage of the overvoltage, undervoltage or phase), the delay is set automatically switch to another normal power, but when abnormal power is restored, you can not auto-reply. △ power grid and power generation (F) [for the power grid and power generation systems, the conversion time should be set to 15 seconds] Two-way power grid and power generation, the automatic controller of the grid - power automatic switch, delay instructions issued by the power generation in the grid voltage is less than 85% of rated voltage, power generation instruction (a set of normally open to normally closed contact output). Disconnect the load circuit when the power voltage reaches 85% of rated voltage, the start grid, uninstall instructions to unload the secondary load to another set of normally open normally closed contact output, and then convert connected on-delay power sources. When the grid is back to normal (more than 85% of rated voltage), the intelligent controller logic to determine automatically the load circuit is disconnected from the power sources, switch to the power grid. □ dual power supply dual state System load pairs of sub-state, regardless of the power of the two groups is normal and the system "manual" and "automatic" preset state, the system remains in the double sub-state. Only in the operating keyboard (manual) (automatic), the system is transferred to non-dual sub-state (manual - commonly - standby or automatic - complex - complex) loads have a power supply according to the above treatments. □ protection functions: overload and short circuit protection, phase loss, circuit protection, and voltage, under voltage protection 1 seconds -30 seconds for automatic switching time adjustable (If you need more time please contact with the factory), high-performance single-chip process control, anti-interference ability, high precision protection; small size, high stability, continuous and reliable work and so on. □ with the central computer control communication interface, remote control fire signal output. Noise-free operation, energy saving, in line with the national green electrical product standards. |
Admin>>>
You are the 7939 visitor
Copyright © GuangDong ICP No. 10089450, On Hai Ansuo Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7939 visitor
Copyright © GuangDong ICP No. 10089450, On Hai Ansuo Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility